Teckentrup Fire and Smoke Protection Doors
Steel protection in highly flammable situations
Teckentrup has been offering tried and tested steel protection for many years now. Tailor-made for the surrounding environment and special functions. Teckentrup steel fire-proof doors combine innovative ideas, modern production know-how and the highest processing quality. The new design, tested in accordance with the new European standard EN 1634-1 and DIN 4102 approved, offers even more safety and already fulfils the new European standards. Exclusive design improvements, time-saving assembly benefits and the optimized convenience features make the new fire barriers pioneers in the field of fire protection.
Teckentrup fire-proof doors can be used in all domestic, public and industrial areas. Family homes and large residential complexes as well as hospitals, cinemas, industrial premises, offices, car parks and schools all enjoy high-quality protection.
• Tested in accordance with DIN EN 1634-1 (or DIN 4102)
• Smoke proof in accordance with DIN 18095
• Available as T30, T60 and T90 version
• Single and double leaf version
• Optionally with glazing and upper casing
• Also for oversized dimensions up to 3000 x 4000 mm
• Also for escape routes
• Also available in stainless steel
|
|
The fire-proof Flema roller shutter has been tested to the University of Liege and has obtained a fire resistance of 79 min.
The roller shutter has also been tested and approved as per the CEN1363-1 and CEN 1634-1 European standards.
Our roller shutter has been developed for inside installation and not intensive use only.
|
|
The fire-proof Flema sectional door has been tested to the laboratory Warringtonfiregent in Gand and has obtained a fire resistance of 68 min.
The door has also been tested and approved as per the CEN1363-1 and CEN 1634-1 European standards.
Our sectional doors has been developed for inside installation and not intensive use only.
|
|
Fire doors not only function as they should in preventing the spread of fire moving through openings, but also comply with all of the known legislative requirements.
KONE only manufacture, install and maintain fire doors that fully comply with the Loss Prevention Certification Board, meeting all of the stringent standards required by insurance companies.
These fire doors are designed to be fitted in internal
applications in a variety of wall constructions. The fire doors are suitable for any building type where fire protection is paramount.
Our steel fire door construction can offer strength, security and durability extended fire resistance. They will not warp, rot or support infestation by vermin or
insects.
|
|
Swing and slide doors with UL 1784 smoke-rated label and mini-blind glass.
The new integrated mini-blind smoke-rated door system is a win-win for patients, hospital personnel, and architects. For patients, the mini-blind glass gives privacy in their most vulnerable state. For hospital personnel, the system provides adjustable light attenuation and eliminates the use of drapes reducing the risk of nosocomial infections. For architects, the smoke-rated label allows greater flexibility in ICU designs where the doors could be located on a fire-rated corridor or in a non-rated suite.
|
|
|
Fire Doors are rated physical fire barriers that protect wall openings from the spread of fire. They provide automatic closing in the event of fire detection with governed speed control. Fire doors are also designed for daily use to provide security and access control, but are for use in openings that are not part of a required means of egress. Cornell offers a complete line of labeled rolling doors for protection in wall openings where rated doors are required by building codes and for insurance purposes.
|
|
|
|
|
|
DOOR FRAME
- Out of sheet steel 20/10e to be sealed by folding of 43 X 18mm out of 4 faces receiving an intumescent lip seal peripheral
- Anchoring with carcass work by sealing fastenings
CASEMENT
- 2 casements or semi-fixed thickness 54mm with covering of rabbet of door frame on 3 sides
- Interior and external Facings sheet 10/10e électrozinguée
- Framework on interior frame composed of a whole of profiles 20/10e assembled by tack welding
- Insulation by plasterboards laid out on both sides of the interior frame with rockwool and intumescent joint in periphery of casement
- Door-fitting 3 hinge plates with board weld steel onto the frame steel
- Side pivot 1 anti-dégondage bolt
- Lock to lard 1 point of closing operated by cylinder with European profile standard Alpha
- Crutch Unit doubles standard GASCOGNE and chrome plates of cleanliness
- Cremone bolt fireman on semi-fixed 2 points of closing
- Panic bar 1 point or 3 points firebreak 1:00 tested with the door
- 1 door closer arm with slide DAD12 firebreak 1:00 tested with the door
COMPLETION
- Anti-corrosive Resin 100% Polyester cooked with the oven
|
|
UNI 9723 REI 60 and REI 120 fire door
When the preservation of people’s lives is the main reason for fire protection. Idra is the most adaptable and rigorous answer, because it has been created for the protection of homes, supermarkets, warehouses, machine rooms, cinemas and public buildings. Made even safer and more functional by the numerous accessories available, and due to its insulating qualities is the Italian fire door that has been able to foresee the new and more severe laws.
Idra is also available in a soundproof version thanks to the special seals.
|
|
|
Hörmann has been manufacturing tested security doors for decades, in compliances with the recommendations of security experts, insurance companies and the police for the many different areas requiring security both indoors and out. This means security that provides effective protection. For you, your family and your valuables. With this brochure we would like to inform you as to what features make a good security door. Your Hörmann specialist will help you to precisely match the level of security to your individual requirements. Benefit from their expertise! It’s never too late for extra security.
|
|
|
The Special-Lite® SL-21 Fire-Rated FRP-Clad Door is the perfect complement to our FRP entrance doors for interior or exterior applications that require a fire-rated door. Tested in accordance with UBC 7-2, NFPA 252, and UL 10C requirements, the SL-21 has passed the 1-1/2 hour positive pressure test, hose stream test, and 250 °F (121 °C) temperature rise tests to achieve Warnock Hersey listing for fire-rated applications in the United States. The SL-21 is available with 30, 45, 60 or 90-minute fire-ratings.
|
|
|
The EI60 aluminium fire-resistant construction is based on Schüco Firestop II and provides 60 minutes of fire resistance for door and wall units in accordance with DIN EN 1634. Country-specific test reports are available. In addition to providing effective fire and smoke protection, the fire-resistant system has optional fittings that offer additional functions such as emergency door or access control, which can be incorporated into the building automation system. The robust 3-chamber profile system has impressively narrow sight lines, slender barrel hinges and a concealed door closer. Its compatibility with the Schüco Firestop II and Royal S systems also presents numerous design options.
|
|