CALIANE - The single DEX technology (Direct Expansion)
Ground heat is absorbed using buried loops, a system of polyethylene-coated copper coils containing refrigerant fluid.
The loops are buried 60 cm below the ground, over a surface area that is 100% to 120% the size of the home to be heated.
A hydraulic distribution circuit transfers the useful heat into the house via a underfloor heating, radiators (maximum temperature of 47°C) or any other solution that uses hot water to transmit heat.
|
|
- User friendly control and monitoring system
- Low noise level
- Easy installation
- Intelligent defrosting
- Anti corrosion coated condenser fins
- Heat recovery for exhaust air as option
|
|
50RHC006-060 and 50RVC009-060 units cover Standard (60° to 95° F) range commercial waterloop (boiler/tower) new and replacement type applications.
All Commercial water-to-air Water Source Heat Pumps are packaged water-to-air units, which are factory wired, piped, charged with refrigerant R-22, tested, and ready for installation.
|
|
|
|
|
|
Water chiller
WSAN-XEE: heat pump
WSAT-XEE: cooling only
Air cooled
Outdoor installation
Capacity from 24,3 to 72,2 kW
Liquid chillers and heat pumps of the ELFOEnergy WSAT-XEE and WSAN-XEE series are units designed for outdoor installation and best energy efficiency in relation to their reduced size.The ELFOEnergy series has been the turning point in the evolution of chillers.Every unit has been conceived and made by applying state-of-the-art technology,emphasising the qualities of EFFICIENCY, SELF-ADAPTATION and EASY INSTALLATION that distinguish this product Thanks to its constructional and electronic peculiarities, ELFOEnergy permits:
-high energy efficiency, in particular during partial-load operation, thanks to the use of two compressors with different capacities that work on a single refrigerant circuit;
-Eurovent energy efficiency classification class "A" in heating operation,also in full load condition;
-adaptability of operating parameters to the load conditions of the connected system, thereby optimising consumption, efficiency and working life of the parts;
-easy, quick installation thanks to the standard hydronic group and the factory test carried out prior to dispatch;
-installation of hydronic group with non-standard working head pumps or with double pump.
|
|
|
|
|
|
Water chiller
WSAN-XSC: heat pump
WSAT-XSC: cooling only
Air cooled
Outdoor installation
Capacity from 163 to 493 kW
The R-410A SPINchiller series presents a new concept of chiller offering:
-EFFICIENCY that increases as the heating load decreases, while guaranteeing maximum requested load when necessary. SPINchiller always ensures maximum comfort with very high efficiency and consequently considerable energy savings;
-a modular approach. Several basic units may be connected together to form a single structure according to the required capacity. This allows high production standardisation and therefore utmost operating RELIABILITY;
-simple unit-system combination, since these units are SELF-ADAPTING to the characteristics of the actual system, thereby avoiding delicate, timeconsuming calibrations. Easy connection to the service system plus a simple control system and easy maintenance drastically reduce work requiring specialised personnel with consequent reduction in installation costs;
-extended operating limits to keep the system running, even under exceptional start-up and load conditions;
-customisation of the unit, also for special requirements both in the civil and technological air-conditioning sphere, thanks to the many available optional accessories. The ECOBreeze and HydroPack accessories in particular enhance the qualities of flexibility and energy efficiency. The latter, for example, consistent with the concept of modularity, has several pumps in parallel with the possibility of reserve pump, to monitor the system load variations better and to regulate the water flow in the critical system starting (or restarting) stages so that outside servicing is avoided.
|
|
The Daikin Altherma total heating and cooling system is based on heat pump technology and represents a flexible and cost effective alternative to a fossil fuel boiler, with a cooling and sanitary warm water option.
The inherent energy efficiency characteristics of Altherma makes it an ideal solution to reduce energy consumption and CO2 emissions.
|
|
9 sizes from 19kW to 79kW
Chlorine free R407c green refrigerant
Scroll compressor design - Single circuit
Integrated Hydronic ModuleIntegrated Hydronic Module
High Static Axial Fans for Ducted Applications - 100 to 150 Pa
Direct Drive Axial Fan : no belt, no air flow adjustment at start-up
User friendly Prodialog Plus control with direct display machine main parameters : temperatures, pressures and CCN Clock board functionalities as standard*
|
|
12 sizes from 40 to 222kW of Heating Capacity
Easy installation : Aquasnap includes an integrated hydronic module and a standard disconnect switch
Exceptional quiet operation: all units have scroll compressors and low noise shrouded Flying Bird II fans.
Chlorine free R407c green refrigerant
User friendly Prodialog Plus control with direct display machine main parameters : temperatures, pressures.....
Easy integration into any building thanks to reduced footprint and low profile
Standard Protection Grills
|
|
To replace your boiler gas or fuel, divide your energy invoice by four. Compatible with the circuits standard radiators with a temperature d%u2019eau being able to reach 65° C.
- Reversible to offer airconditioning
- D%u2019eau medical Production hot in continuous flow
- Connection on exchanger for heating of pool and/or jacuzzi
Rare fact on the market of the ENR:
Our COP include the incidence of de-icing, and are announced of -15°C with +25°C.
These stations of eco heating are intended for the industrial sector but also for the infrastructures for which the requirements out of domestic hot water are important: Hotels, restaurants, centers of balneotherapy, hydrotherapy, thalasso, centers sporting, etc
It is also appropriate for the dwellings for which the energy needs are important (Lodgings, house of hosts, or private habitat comprising a pool).
|
|
To replace your boiler, divide your energy invoice by four.
- Compatible with the circuits standard radiators with a water temperature being able to reach 65° C.
- Reversible to offer airconditioning
- Compatible with the medical production of warm water in great quantity.
- Coupling on plate heat exchanger for the heating of pool/jacuzzi.
EXAMPLE: TRI 30KW 400 VOLTS 50HZ Curve of 0,6 for heating floor
COP with -15°c with INCIDENCES OF DE-ICING: 2,46
COP with +14°c with INCIDENCES OF DE-ICING: 5,86
Stations of eco heating of 20kw with 100kw for habitat, writing desks, hotels, multifamily apartment, industrial building.
|
|
|
|
|
|
To replace your boiler, divide your energy invoice by four. Compatible with the circuits standard radiators with a temperature d%u2019eau being able to reach 65° C.
Reversible to offer airconditioning, compatible with the medical production d%u2019eau hot and the heating of pool.
D%u2019énergie transfer, or how to air-condition your habitat, to recover the calories and to restore them with your domestic hot water or your pool. So that our children do not pay our comfort. Not to more produce CO2, of Nox or other pollutants. To decrease our energy consumption l%u2019environnement in a spectacular way while respecting.
There exists a innovating system which recovers its energy since l%u2019air external to heat and air-condition your habitat.
eco heating: comfort, wellbeing, ecology.
Cast solid unit placed at l%u2019exterior, simple to connect, it is equipped d%u2019un reversible hydraulic system for heating and the d%u2019énergie transfer.
Machine consuming of l%u2019énergie electric having for main feature to restore on average over a qu%u2019elle year between 3 and 4 times more d%u2019énergie calorific does not consume d%u2019énergie electric.
|
|
|
|
|
|
Water chiller
WDH: cooling only
Water cooled
Indoor installation
Capacity from 408 to 1537 kW
The experience gained by Clivet in the high-capacity chiller sector has resulted in the WDH series, with the following features:
-EFFICIENCY - Eurovent energy efficiency Class A and B thanks to the new high capacity screw compressors and to the shell-and-tube exchangers specially developed for the gas R-134a: the best compromise to boost efficiency while limiting costs. The compressors are managed with continuous adjustment of the capacity. The heat exchangers are specifically sized for best adaptation to the other parts of the refrigerant circuit. The latter is fitted with an economiser exchanger for further operating efficiency;
-SELF-ADAPTATION - New, modern and intelligent electronic control directly developed by Clivet. This customisation allows better management of all the circuit components.Continual adapting of chiller operating parameters to the load conditions of the system in which it is installed reduces consumption while the working life of the parts increases;
-STURDINESS - Load-bearing frame in enamelled hot-galvanised sheet metal with semi-hermetic double-screw compressors and shell-and-tube evaporator ensuring reliability and constant performance.
These units may be combined with the dry coolers of the REM series.
|
|
|
|
|
|
Water chiller
Water cooled
Indoor/outdoor installation
Capacity from 197 to 511 kW
The WSH-SC units belong to the SPINchiller family and therefore feature high energy efficiency, self-adaptation and reliability.
-Compactness: when designing the unit special attention was paid to reducing the dimensions of the front as much as possible. The width in the units up to 500 kW capacity has been reduced to just 85 cm so that they can pass through normal doorways.
-Special attention has been paid to making connection to the service system easy so that work requiring specialised personnel is drastically reduced thereby allowing installation costs to be cut considerably. This same policy ensured that attention was paid to easiness of controls and maintenance on all the most sensitive parts.
-EFFICIENCY that increases as the heating load decreases, while guaranteeing maximum requested load when necessary. SPINchiller always ensures maximum comfort with very high efficiency and consequently considerable energy savings;
-The particular abundance of optional accessories allows customisation of the unit, also for special requirements both in the civil and technological air-conditioning sphere. In particular the optional for the HydroPack water circulating unit, consistent with the concept of modularity, has several pumps in parallel (up to 3), to monitor the system load variations better and to regulate the water flow in the critical system starting (or restarting) stages so that outside servicing is avoided.
|
|
EHW Residential heat pump
Water-water chiller with water circulating assembly utility side
Optional: Remote controller (cod. 07225040).
Optional: Pressure valve for cooling mode (part no. 07225010 or part no. 07225020), for reducing condenser water consumption. In chiller heat pumps, this valve must be by-passed by another valve when the unit i
|
|
Energy from the ground can be used by a heat pump to provide useful energy to heat the home. Ground source heat pumps offer excellent energy savings as up to 75% energy for heating can be extracted from the ground.
geoTHERM is the ideal solution for heating your home. geoTHERM can be connected to a suitable high performance hot water cylinder for domestic hot water and to an underfloor heating or radiator system for space heating.
|
|
Energy from the ground can be used by a heat pump to provide useful energy to heat the home. Ground source heat pumps offer excellent energy savings as up to 75% energy for heating can be extracted from the ground.
geoTHERM ground source heat pumps are the ideal solution for heating your home. They can be connected to a suitable high performance hot water cylinder for domestic hot water and to an underfloor heating or radiator system for space heating.
geoTHERM exclusive offers a complete solution to your home comfort providing heat in the winter, cooling in the summer and domestic hot water throughout the year, all from a single unit.
|
|
Air/Water heat pump "TeamAO"
FRISQUET provides a heat pump solution of which the main features are to be high efficient, reliable, and also to be very easy to fit up and to use. The last but not the least, TeamAO provides a real heating comfort.
With a range of 8 kW and 11 kW, single or three phase, and an efficiency COP to 4.1, the heat pump TeamAO apply to low energy houses and on the other hand, can perfectly be installed with gas or fuel boilers, or can store an electric resistor (2-4-6 kW stage). In this case, TeamAo constantly measures the COP value and automatically works at the low cost energy.
The TeamAO's supply corresponds to 2 UNITS :
- an outdoor unit with inverter system and heat exchanger. It already contains refrigerant fluid R410A.
- an indoor hydraulic unit whith control and regulating device
|
|
|
The hot-water heaters Thermodynamiques Hekia (or heat pump for Domestic hot water) recover up to 75% of free energy. A cellar, a garage, a boiler room or a linen room are ideal parts for an active recovery of heat. The waste heat of a boiler or dry a linen, of a freezer or refrigerator, it is as many calories recovered by the heat pump to heat free your Domestic hot water by improving its output.
|
|
| ... products without information |
| |
... see all the products in the category
Heat pumps
|
|
|