The solar hot-water heater with forced circulation consists from one to three solar collectors, a balloon of storage and a power transfer unit GIORSOL. Traditional, this system uses a liquid antifreeze as coolant to recover the energy absorptive by the sensors and to transmit it via an exchanger, with the balloon of storage.
|
|
Vitrified Interacumulador of a coil with coating. For volumes from 160 up to 930 liters, of only 1 coil. Inner and outer use. Deposit standing up. For facilities of joint use of up to 930 liters with inner interchange.
Solar Interacumulador DESCRIPTION with a coil
CAPACITY 160, 200, 300, 500, 800 and 930 ls
TYPOLOGY vertical Installation. Accumulation ACS
MATERIAL vitrified Steel (DIN 4753)
ISOLATION rigid Foam injected polyurethane
FINISHED OUTER quilted polypropylene Lining detachable
|
|
Epoxy storage cell: For facilities that require important volumes of accumulation with outer interchange.
DESCRIPTION: Solar storage cell without coil
CAPACITY (l): 1000, 1500, 2000, 2500, 3000, 3500, 4000 and 5000
TYPOLOGY: Accumulation ACS
MATERIAL: Steel with epoxy coating of quality
nourishing
ISOLATION: Rigid foam polyurethane injected in mold
FINISHED OUTER: Quilted polypropylene lining detachable
|
|
|
The model Mark 3, closed circuit complete thermosiphonic system, is available in various sizes and supports (inclined and flat roof). The tank features a big round flange for easy service and its cover is aluminum granulated with high quality plastic cover. The collector is a Sandwich type. The absorber is made of 2 sheets of thick steel (8 mm) with integrated canals, painted in special solar black colour. The range of Mark 3 model extends from the model 125/1.5 with a tank of 125 liters and one collector of 1.5 m2 and ends up to 300 liters combined with 4,4 or 5,1 m2 of collectors.
|
|
|
The Calpak Vacuum 160/14 VTN and 200/16 VTN are our latest innovations. They are closed circuit thermosiphonic systems with a vacuum tube collector. The vacuum tubes are equipped in the interior with U shaped copper tubes and aluminum fins that maximize the absorbance of heat.
|
|
|
The model Giga NS Selective, closed circuit complete thermosiphonic system, is available in various sizes and supports (inclined and flat roof). The tank features a big round flange for easy service and its cover is white with high quality plastic cover. The collector is high Selective which is a flat plate single copper sheet absorber, with laser welded copper tubes. The range of Giga NS Selective model extends up to 200 liters combined with 4,4 m2 of collectors.
|
|
The PHOENIX solar stations include all the components necessary for optimum operation of the solar heating system.
They are equipped with high quality, speed-variable pumps that increase the system yield and reduce the electricity consumption. Thermometers in the supply and return pipes show whether the solar heating system is working flawlessly. In addition, the stations are equipped with the required safety technology. This includes a manometer, a safety valve and a sufficiently sized expansion vessel to compensate for fluctuations in volume. Since almost all components are already pre-assembled, this simplifies the installation of the PHOENIX system even more.
|
|
|
The forced circulation system consists of a floor standing tank, high selective flat collectors and a solar station with an automatic controller. The kit also includes an electrical resistance, supports for flat and slopping roofs, connection bolts, an expansion tank, anti-corrosive and anti-freezing fluid.
|
|
|
The forced circulation system consists of a floor standing tank, CPC collectors with vacuum tubes and a solar station with an automatic controller. The kit also includes an electrical resistance, supports for flat and slopping roofs, connection bolts, an expansion tank, anti-corrosive and anti-freezing fluid.
|
|
Over recent years, there has been an increasing trend towards utilisation of renewable sources of energy. In order to meet this demand, Gorenje has developed the KGV combined water reservoir, which can be used in the central heating systems in combination with solar collectors and other energy sources.
KGV water reservoirs are the result of many years of research and experience in the field of water heaters. Manufactured from high-quality steel sheet, the KGV is enamelled and provided with a magnesium protective anode.
Inside, one or two smoothbore heat exchangers have been built in for fast heating and high permanent capacity.
Insulation manufactured from hard CFC-free polyurethane with an average thickness of 57 mm provides high thermal insulation.
Option: HEAT PUMP installation.
|
|
Vitocell cylinders deliver hot water quickly on demand, with only around 1'C of heat loss during a 24 hour period.
Hi-grade stainless steel ensures a long service life and very low heat loss. The large dimensioned heat exchangers reach right to the cylinder floor, to heat the entire water content.
|
|
Characteristics
The solar hot-water heater Mondo 200-1 is a system "Low-Flow" with gravitating drainage. It comprises:
1 solar collector ecosol 2.32 high performance with tempered glass treated with anti-reflecting layers.
1 tank of 200 liters to two exchangers and possibility of integration of an electrical resistance of 2 kw.
1 Dynasol system which comprises:
1 intelligent electronic regulation "Alef " which controls the system but also measurement the solar profit and indicates it on the screen of the controller.
1 system of positive-displacement pump integrated which ensures the optimal flow in the solar circuit.
|
|
Characteristics
The solar hot-water heater Mondo 500-3 is a system "Low-Flow" with gravitating drainage. It comprises:
3 solar collectors ecosol 2.32 high performance with tempered glass treated with anti-reflecting layers.
1 tank of 500 liters to two exchangers and possibility of integration of an electrical resistance of 2 kw.
1 Dynasol system which comprises:
1 intelligent electronic regulation "Alef " which controls the system but also measurement the solar profit and indicates it on the screen of the controller.
1 system of positive-displacement pump integrated which ensures the optimal flow in the solar circuit.
|
|
Characteristics
The solar hot-water heater Mondo 300-2 is a system "Low-Flow" with gravitating drainage. It comprises:
2 solar collectors ecosol 2.32 high performance with tempered glass treated with anti-reflecting layers.
1 tank of 300 liters to two exchangers and possibility of integration of an electrical resistance of 2 kw.
1 Dynasol system which comprises:
1 intelligent electronic regulation "Alef " which controls the system but also measurement the solar profit and indicates it on the screen of the controller.
1 system of positive-displacement pump integrated which ensures the optimal flow in the solar circuit.
|
|
Characteristics
The solar hot-water heater Mondo 500-2 is a system "Low-Flow" with gravitating drainage. It comprises:
2 solar collectors ecosol 2.32 high performance with tempered glass treated with anti-reflecting layers.
1 tank of 500 liters to two exchangers and possibility of integration of an electrical resistance of 2 kw.
1 Dynasol system which comprises:
1 intelligent electronic regulation "Alef " which controls the system but also measurement the solar profit and indicates it on the screen of the controller.
1 system of positive-displacement pump integrated which ensures the optimal flow in the solar circuit.
|
|
The ESSENTIAL SUPPLEMENT HEATING HAS YOUR SOLAR INSTALLATION!
The AE.SOLAIRE is an auxiliary module and of regulation for the circuit heating of the solar installations with modulating valve troies ways built-in.
ELECTRIC SUPPLEMENTS FOR SOLAR INSTALLATION
The electric boilers of series AE.SOLAIRE are designed for an installation in supplement on the circuits heatings of the solar balloons.
The AE.SOLAIRE is the pilot of the boiler room managing the contribution of the solar balloon and the electric stages additional.
|
|
|
A forced circulation system is necessary when the boiler is placed lower than the solar collectors and also has different characteristics.It thus requires the following accessories to function: circulating unit to keep the fluid flowing and a differential electronic control system that is sensitive to panel and boiler temperatures that also regulates the circulating unit. The principle characteristic of this system is very high efficiency.
|
|
Natural circulation systems function by the principle that the convection fluid, as it heats up, will naturally go upwards, will exchage heat and then go down.
These systems have: An excellent efficiency, Low maintenance, No electronic or electric appliances are necessary to function.
|
|
The hemo solar storage tank places at disposal domestic hot water and for heating and is connected to a boiler. This engages automatically if sunlight is not enough to establish the required temperature
hemo solar panel with vacuum pipe complete with: “thermos principle” vacuum pipe direct flow system and dry connection pipe, dish mirror.
|
|
Sunerg hot water boilers come in various models based on the specific requirements and the number of exchangers requested.
They are finished with glaze and guaranteed 5 years. It is possible also to install different models if requested specifically.
These boilers are not adequate for integration with heating systems and are specifically for positioning within homes. The colors, the measurements and the bindings can vary without notice, if and when specific requirements are needed they must be requested directly to our head quarters and included on confirmation order.
|
|
| ... products without information |
| |
|
|