The SOLAR UPEC comprises gone up, tested and regulated of factory:
- a balloon of 300 or 400 liters,
- a Solar regulation System control,
- a hydraulic station,
- temperature sensors of the balloon,
- a surge tank of 25 liters,
- dielectric connections,
- 30 liters of coolant and antifreeze ready with employment.
For an implementation simple and fast.
It is enough to connect to it provided electric cable and already racordé, with a power supply.
|
|
| The Calpak Vacuum 160/14 VTN and 200/16 VTN are our latest innovations. They are closed circuit thermosiphonic systems with a vacuum tube collector. The vacuum tubes are equipped in the interior with U shaped copper tubes and aluminum fins that maximize the absorbance of heat. |
|
| The model Mark 3, closed circuit complete thermosiphonic system, is available in various sizes and supports (inclined and flat roof). The tank features a big round flange for easy service and its cover is aluminum granulated with high quality plastic cover. The collector is a Sandwich type. The absorber is made of 2 sheets of thick steel (8 mm) with integrated canals, painted in special solar black colour. The range of Mark 3 model extends from the model 125/1.5 with a tank of 125 liters and one collector of 1.5 m2 and ends up to 300 liters combined with 4,4 or 5,1 m2 of collectors. |
|
| The model Giga NS Selective, closed circuit complete thermosiphonic system, is available in various sizes and supports (inclined and flat roof). The tank features a big round flange for easy service and its cover is white with high quality plastic cover. The collector is high Selective which is a flat plate single copper sheet absorber, with laser welded copper tubes. The range of Giga NS Selective model extends up to 200 liters combined with 4,4 m2 of collectors. |
|
Characteristics
The solar hot-water heater Mondo 500-3 is a system "Low-Flow" with gravitating drainage. It comprises:
3 solar collectors ecosol 2.32 high performance with tempered glass treated with anti-reflecting layers.
1 tank of 500 liters to two exchangers and possibility of integration of an electrical resistance of 2 kw.
1 Dynasol system which comprises:
1 intelligent electronic regulation "Alef " which controls the system but also measurement the solar profit and indicates it on the screen of the controller.
1 system of positive-displacement pump integrated which ensures the optimal flow in the solar circuit.
|
|
Characteristics
The solar hot-water heater Mondo 500-2 is a system "Low-Flow" with gravitating drainage. It comprises:
2 solar collectors ecosol 2.32 high performance with tempered glass treated with anti-reflecting layers.
1 tank of 500 liters to two exchangers and possibility of integration of an electrical resistance of 2 kw.
1 Dynasol system which comprises:
1 intelligent electronic regulation "Alef " which controls the system but also measurement the solar profit and indicates it on the screen of the controller.
1 system of positive-displacement pump integrated which ensures the optimal flow in the solar circuit.
|
|
Characteristics
The solar hot-water heater Mondo 300-2 is a system "Low-Flow" with gravitating drainage. It comprises:
2 solar collectors ecosol 2.32 high performance with tempered glass treated with anti-reflecting layers.
1 tank of 300 liters to two exchangers and possibility of integration of an electrical resistance of 2 kw.
1 Dynasol system which comprises:
1 intelligent electronic regulation "Alef " which controls the system but also measurement the solar profit and indicates it on the screen of the controller.
1 system of positive-displacement pump integrated which ensures the optimal flow in the solar circuit.
|
|
Characteristics
The solar hot-water heater Mondo 200-1 is a system "Low-Flow" with gravitating drainage. It comprises:
1 solar collector ecosol 2.32 high performance with tempered glass treated with anti-reflecting layers.
1 tank of 200 liters to two exchangers and possibility of integration of an electrical resistance of 2 kw.
1 Dynasol system which comprises:
1 intelligent electronic regulation "Alef " which controls the system but also measurement the solar profit and indicates it on the screen of the controller.
1 system of positive-displacement pump integrated which ensures the optimal flow in the solar circuit.
|
|
Description:
Balloons available in 300,400 and 500 liters, simple exchanger Sensor of 2,02 m ². Pressurized operation
A coolant circulates between the sensors and the exchanger of the balloon. It heats in the sensors such water in a pipe of watering to the sun. It transfers then its calories to medical warm water from the balloon through the exchanger. Operation is controlled by a solar regulation. This one activates or decontaminates the pump of the solar circuit. When the temperature of instruction is reached (75°C) or that the sunning is insufficient, the regulation cuts off the supply of the pump. The coolant being immobilized, it has there no more transfer of heat. In the event of weak sunning, it is the boiler assembled in series with the solar balloon which ensures the supplement in energy.
|
|
BOILERS WITH BACK UP ELECTRIC RESISTANCE
Boilers get its heating energy from solar collector / central heating system or electricity and produce potable hot water. Fluid in the serpentines provides heat transfer water to water via transferring its heat energy to water in inner tank or heating elements will heat water. Thus potable hot water will be produced.
Cylinder type hot water tank and serpentines in the tanks is coated with immersing to hot galvanize. Thus anode rod is not needed and you save your time and cost for changing anode rod. Due to special coating material heat transfer is faster and heating efficient is high.
You can observe water temperature with thermometer. You can set desired temperature with adjustable thermostats mounted to sensor holes. When water temperature has achieved desired temperature, thermostat will send a signal then circulation and recirculation pumps will be out off service. Thus it will prevent waste operation.
Especially in summer periods you can provide hot water with electrical supply without using central heating system. If you use DCSB-X and DTSB_X Series model with electrical command panel ask for temperature pressure valve which provides discharging excess water/steam pressure and temperature. |
|
The ESSENTIAL SUPPLEMENT HEATING HAS YOUR SOLAR INSTALLATION!
The AE.SOLAIRE is an auxiliary module and of regulation for the circuit heating of the solar installations with modulating valve troies ways built-in. |
|
Vitrified Interacumulador of a coil with coating. For volumes from 160 up to 930 liters, of only 1 coil. Inner and outer use. Deposit standing up. For facilities of joint use of up to 930 liters with inner interchange.
Solar Interacumulador DESCRIPTION with a coil
CAPACITY 160, 200, 300, 500, 800 and 930 ls
TYPOLOGY vertical Installation. Accumulation ACS
MATERIAL vitrified Steel (DIN 4753)
ISOLATION rigid Foam injected polyurethane
FINISHED OUTER quilted polypropylene Lining detachable |
|
| The forced circulation system consists of a floor standing tank, high selective flat collectors and a solar station with an automatic controller. The kit also includes an electrical resistance, supports for flat and slopping roofs, connection bolts, an expansion tank, anti-corrosive and anti-freezing fluid. |
|
| The forced circulation system consists of a floor standing tank, CPC collectors with vacuum tubes and a solar station with an automatic controller. The kit also includes an electrical resistance, supports for flat and slopping roofs, connection bolts, an expansion tank, anti-corrosive and anti-freezing fluid. |
|
BOILERS WITH SINGLE/DOUBLE HEAT EXCHANGERS
Boilers with heat exchanger(s) get its heating energy from solar collector or central heating system and produce potable hot water. Fluid in the serpentines provides heat transfer water to water via transferring its heat energy to water in inner tank. Thus potable hot water will be produced.
Cylinder type hot water tank and serpentines are coated with immersing to hot galvanize. Thus anode rod is not needed and you save your time and cost for changing anode rod. Due to special coating material heat transfer is faster and heating efficient is high.
You can observe water temperature with thermometer. You can set desired temperature with adjustable thermostats. When water temperature has achieved desired temperature, thermostat will send a signal then circulation and recirculation pumps will be out off service. Thus it will prevent waste operation.
DCSB and DTSB series boilers are available for additional heating elements. Thus, especially in summer periods you can provide hot water with electrical supply without using central heating system. If you use DCSB-X and DTSB_X Series model with electrical command panel ask for temperature pressure valve which provides discharging excess water/steam pressure and temperature. |
|
This sophisticated further development of the thousand fold proven Ökocell triple zone tank can be flexibly used and will impress you with its high performance. Due to the high efficiency of the heat exchanger surface area, the H3 uses the flow principle to deliver sufficient fresh hot water of extraordinary quality - every time.
The stainless steel corrugated pipe element with a large heating area replaces the hot water tank. The H3 is best combined with wood, oil or gas heating systems. Treat yourself to this added quality of life and health!
|
|
Epoxy storage cell: For facilities that require important volumes of accumulation with outer interchange.
DESCRIPTION: Solar storage cell without coil
CAPACITY (l): 1000, 1500, 2000, 2500, 3000, 3500, 4000 and 5000
TYPOLOGY: Accumulation ACS
MATERIAL: Steel with epoxy coating of quality
nourishing
ISOLATION: Rigid foam polyurethane injected in mold
FINISHED OUTER: Quilted polypropylene lining detachable |
|
Solar hot-water heater range domesticates Giorsol
The solar hot-water heater with forced circulation consists from one to three solar collectors, a balloon of storage and a power transfer unit GIORSOL. Traditional, this system uses a liquid antifreeze as coolant to recover the energy absorptive by the sensors and to transmit it via an exchanger, with the balloon of storage.
- Standard solar hot-water heater GIORSOL is very FUNCTIONAL: several indicators of control make it possible to check the good performance of the installation permanently.
- It is FLEXIBLE: Jacques giordano industries proposes a broad range of hot-water heater GIORSOL going from 100 liters to 550 liters, likely to adapt to various configurations: vertical or horizontal sensors, balloons manufactured with an enamelled coating or out of stainless steel.
|
|
| The solar hot-water heater with forced circulation consists from one to three solar collectors, a balloon of storage and a power transfer unit GIORSOL. Traditional, this system uses a liquid antifreeze as coolant to recover the energy absorptive by the sensors and to transmit it via an exchanger, with the balloon of storage. |
|
CESI/BALLONS/
Ballon Solaire Doubles Exchanging 200 L
code produces: 1413000400
height: 1585 mm
diameter: 500
volume: 200 liters
weight: 62 kg
conditioning: 1 part/parcel
color: white |
|
Vitocell cylinders deliver hot water quickly on demand, with only around 1'C of heat loss during a 24 hour period.
Hi-grade stainless steel ensures a long service life and very low heat loss. The large dimensioned heat exchangers reach right to the cylinder floor, to heat the entire water content. |
|
Solar thermal collectors VELUX are integrated in any discretion on all the roofs. The use of same connections of sealing as for guaranteed roof windows VELUX an integration made safe in all breeder materials (mechanical roof tiles, roof tiles channel, slates...) and all slopes of roof starting from 15°, as well as a perfect sealing.
Moreover, of the same size than roof windows VELUX, the solar collectors combine harmoniously and in configurations varied with them, so that the roof becomes source of energy and light.
2 solutions of pack balloon to be coupled with solar collectors VELUX:
For the restoration: pack solar balloon VELUX
For the nine: pack solar balloon MG-V ATLANTIC
FEATURES:
Copper absorber covered with a highly selective coating.
Profiled out of dark gray enamelled aluminum.
3 dimensions available (L X H): 114 X 118 (surface of collecting of 1,2 m ²); 114 X 140 (1,4 m ²) or 134 X 180 cm (2,2 m ²).
Certification Solar Keymark and Technical opinion 14/07-1136 opening right to the tax credit of 50%
List solar systems VELUX on the site of ENERPLAN for the attribution of regional aids.
Guarantee: 5 years subject to use of flexible devices VELUX. In the contrary case, the Biennial one applies.
|
|
Length: 1776 mm
Width: 1751 mm
Thickness: 110 mm
Surface: 2.75 m ²
Weight: 55 kg
Guarantee: 10 years
|
|
Solar panels:
- Capture the originating energy of the solar radiation.
- Flat Solar Collectors.
- Existence in the market of Compact Systems (use single-family house and inferior quality).
- Location in shelters or roofings. |
|
Tras la entrada en vigor del nuevo Código Técnico de Edificación en el que se recoge la obligatoriedad, para todo tipo de construcciones, del uso de paneles solares térmicos para la obtención de ACS (agua caliente sanitaria), Thermochip ha desarrollado, para todo tipo de cubiertas, un sistema ideal, el THERMOSUN.
El kit THERMOSUN incluye todos los componentes para poder instalar tu colector solar para ACS. Se coloca fácilmente tanto sobre tu cubierta THERMOCHIP como sobre cualquier otro tipo de cubiertas, con un montaje sencillo y versátil, pues permite cualquier tipo de cubrición posterior. Los captadores quedan integrados en la cubierta, mnimizando el impacto visual de la instalación, remplazando de forma segura la cubierta tradicional, y todo ello avalado por la garantía que ofrece THERMOCHIP en sus productos.
THERMOSUN consta de un captador plano de gran rendimiento para montaje en vertical y horizontal. El marco autoportante y la tapa posterior son de aluminio resistente a la corrosión y dispone de un aislamiento térmico de lana mineral en su parte posterior. Debajo del vidrio solar de seguridad con un espesor de 4mm se encuentra un absorbedor homogéneo de cobre de una sola pieza con recubrimiento Sunselect de una absorción altamente selectiva y una fijación mecánica para el absorbedor. La tubería está colocada en forma de meandro y está. conectada mediante pasos tubulares con aislamiento térmico y sin carga |
|
The BP Solar business became profitable for the first time in 2004 after rapid growth and streamlining. Today, we work in almost 100 countries and produce more than 200 MW of solar technology every year. Our work includes everything from designing and manufacturing solar electric systems, through to marketing them to people, businesses and industries. Here are some recent highlights below.
|
|
BIASOL CF
The systems to forced circulation take advantage of the solar energy like carrier for the sanitary warm water production. I use of installed solar collectors on the roof who directly feed a coil kettle double, installabile anywhere inside of a room and through which come scaldata and accumulated the sanitary warm water, allows a remarkable energetic saving. In fact, thanks to the installation of these systems I use, it of the generator to gas takes part with only reduced frequency a lot when this system does not succeed to guarantee the requirements total of the user being implied therefore a remarkable saving in the fuel consumption. |
|
| Collector with vertical configuration with high selective absorber of one copper fin laser welded on the copper tubes. The frame is made of anodized aluminum with tempered glass, insulated with 3 cm thick polyurethane lined inside with aluminum foil and outside with aluminum sheet. |
|
|
|