The ELEACOME range of electric radiating surface systems :
Eléatram is an electric floor heating system used for total or partial heating in private houses, flats and service industries.
Its principle of operation : The floor is heated by a cable at constant power attached to a plastic frame and the combined unit is then laid on an insulating plate in PSE.
Its implementation uses a "wet" solution i.e. under a concrete slab or a fluid screed on which the floor covering will be laid.
|
|
SIPCP Twin heating mat with 1-sided connection
For complete heating (floor storage heating, partial storage and direct heating)
Laying width 90 cm
Sepentine heating conductor mounted on synthetic supporting net
Cold lead length 4 metres, 1-sided connection
For use in dry, humid and wet rooms
With PVC protective jacket for exceptional heat stabilization
Specific linear load max. 25 W/m
|
|
|
Domocâble offers comfort d´une soft and uniform heat and d´un agreeably hot ground without cold zone and circulation to d´air. The temperature of surface of the ground does not exceed 28°C.
|
|
Underfloor heating suitable for fitting around the perimeter of an un-carpeted room which requires high-output heating with a fast response time. Typical applications are garden rooms and galleries, entrance halls, and traditional greenhouses and conservatories.
The heating system uses convectors, set in a duct and covered with grilles and works efficiently off existing central heating without fans or additional pumps. Marston & Langinger offers a design-layout service, and supplies heating convectors, baffles (to improve air circulation), alloy grille-supports, trims, and grilles in various sizes, combinations and patterns. In glass buildings with electric ventilators, a Marston & Langinger automatic controller can be used to operate both the heating and ventilation to give a balanced temperature, whatever the weather outside.
|
|
|
Honeywell Floor Heating systems consist of a Teflon insulated copper alloy resistance heating element sewn to a fiberglass mesh backing. The heating element is evenly spaced in 2” serpentine loops. It also delivers a faster, more even distribution of heat for improved homeowner comfort. The entire system is less than 1/8” thick allowing it to be easily installed under tile and stone without greatly affecting the floor height.
|
|
Honeywell Floor Heating systems consist of a Teflon insulated copper alloy resistance heating element sewn to a fiberglass mesh backing. The heating element is evenly spaced in 2” serpentine loops. It also delivers a faster, more even distribution of heat for improved homeowner comfort. The entire system is less than 1/8” thick allowing it to be easily installed under tile and stone without greatly affecting the floor height.
The fiberglass mesh backing helps to hold the heating element in place for easy, fault-free installation. It also allows the system to be covered directly by the thinset cement used to lay tile or natural stone flooring.
Full room heating systems generally consist of a single Honeywell heating “roll” of predetermined length. The system is placed in position using the easy-to-follow floor layout diagram provided with each kit, with a pre-attached lead that runs to a thermostat and/or junction box for power. No additional installation wiring is required.
|
|
|
|
|
|
Radiant pipe ZENITH is especially designed for high buildings (> 4m). Actually radiant pipe is used when areas heating is preferable to volume heating. Then, it is mostly used for old industrial buildings or city establishment (gymnasium) when insulation is poor.
This range is available in 2 versions : Radiant pipe on line ‘’L’’ or ‘’U’’ disposal. Take care to the radiant pipe arrangement in order to supply comfort and performance on the surfaces covered.
Alimentation : natural gas or propane
4 sizes are possible 13 / 22 / 35 / 50 KW. Installation high are variable according to the nominal power.
AIRCALO can supply alternative in order to increase radiant pipes efficiency as :
Stainless steel reflector for better radiation quality (approx. 5%) et with no alteration in the time.
Double skin reflector are reducing convection losses (approx. 5%) and improve efficiency on floor.
Dilatation bearings are cancelling any friction on pipe, then the length life is improved.
Many accessories : Regulation kit for areas (up to 8 unit by area), gas connection kit, ball grills ... etc
|
|
Equipments suited for all environments with great height (form 4 to 20 meters) or with high thermal dispersion.
It includes a burner unit and a heat exchanger tube which reaches the temperature of 400 ÷ 550 °C., providing a very high radiation efficiency, also by means of the reflecting cover located over the tubes, which focuses the thermal flow downwards.
By means of a centralized equipment control system it is possible to heat only the areas concerned by operations.
|
|
|
Thermal radiation is the natural alternative to traditional warm- air heating systems. Heat only concentrates in the low part of the building, passing through the air without warming it. Only surfaces are heated, offering a great confort quality.
|
|
|
The Sabiana Duck Strip radiant panels are produced in 8 different models, with 2 standard colours, and others upon request. Each model features elements measuring 4 and 6 metres in length (3 and 5 metres upon request). Each element can be easily connected by pressfittings or by welding the pipes (in the latter case the pipes are supplied with belled ends to assist coupling and welding).
|
|
INNOVATIVE CONSTRUCTIVE FEATURES :
•Tubes Ø22 : Zinc plated steel tube diameter 22 mm, which is the nominal size suitable for all the 22 mm pressfittings;
• Pre-painted panel : Radiant panel in zinc lated pre-painted steel;
• Self-supporting frame : Radiant panel with self-supporting frame to offer the best stiffness;
• Flexible installation :Great flexibility in the installation thanks to coupling points at every 1,5 mt maximun flexibility also using the mobile hookers ;
• Asymmetric manifolds : Asymmetric manifolds with balanced flow for a uniform temperature on the panel.
• Temperature : The maximun temperature of the fluid is up to 200°C.
|
|
|
|
|
|
Electric Heating Panel for Wall and Ceiling
Eliminate radiators - heat with wall- or ceiling-panels!
Install the interior panels with electric heating function. The heating is invisible behind the attractive panels on the wall or on the cieling. Close a contract with a green power supplier and you are emission-free at once.
Surface Material:
The surface is a fine, grainy sand structure with one or more colours and with arbitrary structures. The surface is durable and the colours are stable over time.
Core Material:
The surface is coated onto sheets or cassetts from aluminium, but on request other core materials are also available. On the backside of the panel is a high-tech electric heating foil. The final backside layer is a thermal insulation material that makes sure the heat goes into the room, not into the wall.
Heating Function:
The heating is provided on a large surface with low temperatures - similar to an underfloor heating. The power supply is through a safety transformer of less than 48V. Temperature management is provided by thermostats per room. Combined use of the transformer for LED-lights is possible.
|
|
|
The Pulsar ceiling mounted radiant panels a are made in 4 sizes, with a width of 600 mm and a length between 1.2 and 3 m, in 2 standard colours, and others upon request. The panel has a very elegant design, perfectly matching the false ceiling, features simple maintenance, very long life and can be connected in series or in parallel to others panels using flexible pipes supplied upon request.
|
|
To be
electrical radiating ground
System S.R.E is made up of an electrical resistance with enmeshes self-adhesive that facilitates the installation, in addition incorporates an advanced /programador regulator to optimize the power consumption to the maximum.
|
|
|
|
|
|
THERMBORD - baseboard heating - is a perimeter irradiation heating system. The experiments conducted have proven that this heating system distributes heat perfectly evenly throughout the room, in a manner that is easily understood.
Heat distribution around the floor and irradiation from the walls offer a healthy, comfortable indoor climate: no cold feet, same temperature from head to toe, no cold, damp corners, no respiratory irritation (scratchy throat) - in short, none of the inconveniences encountered with convection heating. It's a brand new sensation of warmth.
The low percentage of convection (ascending heat) forms a veil of warmth in front of cold external walls that absorbs the incoming cold; it cools as it rises, thus avoiding the costly waste of a cushion of heat under the ceiling (energy savings).
Compared to traditional systems, hemo THERMBORD allows you to reduce the room temperature by approximately 3 degrees while maintaining the same comfort level, for energy savings of up to 40%.
|
|
A slimming diet for heated flooring !
The CLIMACOME range of hydraulic radiating surface systems:
Vivracome is a low temperature warm water floor heating system suitable for new or existing floors in private houses, apartment blocks and service industries.
Innovation !
ACOME offers a truly innovative product with a heated floor system only 22 mm thick (excluding floor covering), for use with so-called "dry" solutions, i.e. without a concrete slab or liquid screed.
Its principle of operation is to circulate water through polyethylene tubing (PEX) lying in slots in insulating slabs made in aluminium coated PSE (for improved heat diffusion and homogenisation).
|
|
The CLIMACOME® range of hydraulic radiating surface systems :
Thermacome® is a low temperature warm water system used for total or partial heating and/or cooling in private houses and apartment blocks, in the tertiary sector : offices, factories, schools, hotels, restaurants, churches, etc. and in sports centres : gymnasiums, swimming pools, stadiums, etc.
Its principle of operation is to circulate water through polyethylene tubing (PEX), clipped in place in self-fitting tube guide holders in PSE insulating slabs.
Its implementation uses a "wet" solution i.e. under a concrete slab or a fluid screed on which the floor covering will be laid.
All the components are compliant with the current regulations
|
|