Thermally insulated fire protection door, fire resistance rating 30 minutes
Construction:
Thermally insulated aluminium fire protection construction in accordance with DIN 4102-5 and EN 1634-1 (T30-1 / -2 -FSA and T30-1 / -2 -RS-FSA) for single- and double-leaf doors, opening inwards or outwards, with general building supervisory authority approval Z-6.20-2144
F30 fire resistant glazing in accordance with DIN 4102-13 and EN 1634-1 with general building supervisory authority approval Z-19.14-2049
Without additional fire protection insulating strips in the leaf and frame.
In the event of fire, foaming insulation layer strips integrated in the door and glass rebate area.
Large door and leaf dimensions:
1-leaf max. passage W x H 1458 x 3009 mm
2- leaf max. passage W x H 2858 x 3009 mm
Leaf weight up to 250 kg
Element height walls (fixed glazing) up to 5000 mm
Glass sizes: up to max. 1586 x 3000 mm, vertical and horizontal.
Panel sizes: max. 1400 x 3000 mm, vertical and horizontal.
Various glazing versions, including as triple insulating glass with a Ug value of max. 0.5 W/m2K. Panel inserts optionally with vision panel, with a Up value of max. 0.3 W/m2K
Also according to product standard 16034 with CE marking
Insulating zone:
Factory-mounted low-shear composite, suitable for subsequent powder coating and anodisation
Elevation width: Narrow elevations of the fixed and sash frame combination from 148 mm
Profile depth:
Fixed and sash frame: 77 mm
Flush inside and outside
Highlights:
Uf ≥ 2.0 W/m²K
Water tightness up to class 8A (EN 12208)
Air permeability class 2 (EN 12207)
Resistance to wind load up to class C3 / B3 (EN 12210)