Rigid polyisocyanurate foam insulation panel for roofs
POWERDECK
RECTICEL Insulation France
DESCRIPTION
Panel of heat insulation with a foam heart polyisocyanurate (PIR) rigid (TAUfoam by RECTICEL) covered, on two faces, of a facing seals aluminum corrugated 50 µ (microns)
Strong points
High thermal performance
To R = 10 m ². K/W in 2 beds
Rigid, light, resistant and easy to pose
CHARACTERISTICS
Dimensions of the panels:
2500 X 1200 mm, useful 2485 X 1185 mm
1000 X 1200 mm, useful 985 X 1185 mm
Thicknesses: 30-40-50-60-70-75-80-90-100-120 mm
Panels rabbets: Thickness equal to or higher than 80 mm
Thermal coefficient of conductivity: λ = 0,024 W/m.K
Density of foam: 32 kg/m3 ± 2
Classification of compressibility: ≥ 150 kPa rigid insulation and resistant of class C, traficability classifies 3 (pedestrian intense traffic - test laboratory BDA)
Tensile strength perpendicular: ≥ 80 kPa
Behavior in fire:
Euroclasse B-s2, d0 (on vat steel)
Classification Factory Mutual: Classify 1 (according to various complexes of roofing)
Euroclasse D-s2, d0 (produced only)
SCOPE OF APPLICATION
On roofing vat steel (TAN), wood or derived from wood
Last nines and rehabilitation
All types of buildings (according to specific regulation)
Inaccessible, technical, photovoltaic and vegetalized roofings
IMPLEMENTATION
Pose of them 1 or 2 beds according to DTA
DOCUMENTS
ACERMI N°04/003/329
DTA (Technical opinion)
DTU 43.3/43.4/43.5
Guide use of combustible insulations in ERP appendix 1 of the AM8
Panel of heat insulation with a foam heart polyisocyanurate (PIR) rigid (TAUfoam by RECTICEL) covered, on two faces, of a facing seals aluminum corrugated 50 µ (microns)
Strong points
High thermal performance
To R = 10 m ². K/W in 2 beds
Rigid, light, resistant and easy to pose
CHARACTERISTICS
Dimensions of the panels:
2500 X 1200 mm, useful 2485 X 1185 mm
1000 X 1200 mm, useful 985 X 1185 mm
Thicknesses: 30-40-50-60-70-75-80-90-100-120 mm
Panels rabbets: Thickness equal to or higher than 80 mm
Thermal coefficient of conductivity: λ = 0,024 W/m.K
Density of foam: 32 kg/m3 ± 2
Classification of compressibility: ≥ 150 kPa rigid insulation and resistant of class C, traficability classifies 3 (pedestrian intense traffic - test laboratory BDA)
Tensile strength perpendicular: ≥ 80 kPa
Behavior in fire:
Euroclasse B-s2, d0 (on vat steel)
Classification Factory Mutual: Classify 1 (according to various complexes of roofing)
Euroclasse D-s2, d0 (produced only)
SCOPE OF APPLICATION
On roofing vat steel (TAN), wood or derived from wood
Last nines and rehabilitation
All types of buildings (according to specific regulation)
Inaccessible, technical, photovoltaic and vegetalized roofings
IMPLEMENTATION
Pose of them 1 or 2 beds according to DTA
DOCUMENTS
ACERMI N°04/003/329
DTA (Technical opinion)
DTU 43.3/43.4/43.5
Guide use of combustible insulations in ERP appendix 1 of the AM8
-
zoom