Rigid polyurethane foam insulation panel
POWERLINE
RECTICEL Insulation France
DESCRIPTION
Panel of heat insulation with a rigid foam polyisocyanurate heart (TAUfoam by RECTICEL) covered, on two faces, of a facing seals aluminum corrugated 50 µ (enamelled white on the face connect) rebordé on the long sides
Strong points
High thermal performance
Good fire resistance
Profitability of the breeding and storage
Low thickness, light, easy to pose
CHARACTERISTICS
Dimensions of the panels rebordés and grooved over the length:
Length with the request up to 6,50 m Width 1227 mm
Thicknesses: 30-40-50-60 mm
Thermal coefficient of conductivity: λ = 0,024 W/m.K
Density of foam: 32 kg/m3 ± 2
Classification of compressibility: ≥ 150 kPa
Tensile strength: ≥ 80 kPa
Behavior in fire: Classification Euroclasse D-s2, d0
SCOPE OF APPLICATION
Last nines and Rehabilitation
Insulation of agricultural buildings
Insulation of agro-alimentary buildings (storage)
Breeding, fermenting room, wine storehouses
IMPLEMENTATION
During their fixing, the panels will be well applied the ones against the others so as to ensure an installation on jointed board to avoid the thermal bridges. The longitudinal assembly will be done with sections PETRO Powerline. The transverse assembly will be done with sections PROFISOL Powerline corresponding to the thickness of the panels.
DOCUMENTS
ACERMI N°04/003/323
Panel of heat insulation with a rigid foam polyisocyanurate heart (TAUfoam by RECTICEL) covered, on two faces, of a facing seals aluminum corrugated 50 µ (enamelled white on the face connect) rebordé on the long sides
Strong points
High thermal performance
Good fire resistance
Profitability of the breeding and storage
Low thickness, light, easy to pose
CHARACTERISTICS
Dimensions of the panels rebordés and grooved over the length:
Length with the request up to 6,50 m Width 1227 mm
Thicknesses: 30-40-50-60 mm
Thermal coefficient of conductivity: λ = 0,024 W/m.K
Density of foam: 32 kg/m3 ± 2
Classification of compressibility: ≥ 150 kPa
Tensile strength: ≥ 80 kPa
Behavior in fire: Classification Euroclasse D-s2, d0
SCOPE OF APPLICATION
Last nines and Rehabilitation
Insulation of agricultural buildings
Insulation of agro-alimentary buildings (storage)
Breeding, fermenting room, wine storehouses
IMPLEMENTATION
During their fixing, the panels will be well applied the ones against the others so as to ensure an installation on jointed board to avoid the thermal bridges. The longitudinal assembly will be done with sections PETRO Powerline. The transverse assembly will be done with sections PROFISOL Powerline corresponding to the thickness of the panels.
DOCUMENTS
ACERMI N°04/003/323
-
zoom