Precast reinforced concrete driven pile
Terratest
In all cases they are made of concrete with minimum resistance properties of 45 N/mm2.
Likewise, I 52,5 N/SR (RC-03) cement is always used, which makes the piles resistant to sulphates and seawater.
Both the manufacture and on-site driving of our piles are separately guaranteed by AENOR Quality Assurance certification (UNE-EN ISO standards 9001:2000 and UNE-EN ISO standard 9002:1994).
TERRA prefabricated piles are systematically monitored during their manufacture (raw material reception, resistance and geometry, manufacture, concrete resistance and consistency) both at the factory and on the building site (static and dynamic load testing, integrity trials...l).