Planning and installation - Stil-Kamin 51/67 side-opening door
Tested according to EN 13229 W EN 13229 WA
Values measured at Rated capacity Accumulation
Suitable for all construction types according to rules OK OK
EEI 108.6 108.6
Data for functional demonstration
Fire wood volume kg/h 3.3 5
Combustion performance kW 14 23
Flue gas mass flow g/s 10.5 22
Flue gas temperature after:
attached steel smoke hood °C 190 250
Necessary supply pressure Pa 13 13
Combustion air consumption m3
/h 40 50
Combustion air connection Ø mm 125 125
Heat distribution
Insert / heat accumulator % 30 / 30 30 / 30
Glass pane (single / double) % 40 / - 40 / -
Cross-section of gratings 1)
Supply air cm2 700 / 200 / - 700 / 200 / -
Warm air cm2 700 / 200 / - 700 / 200 / -
Minimal oven surface for closed construction type
Heat dissipating surface m2 5.5 5.5
Minimal distances of the fireplace
to insulation layer cm 8 8
to mounting floor cm 2 2
Thermal insulation without / with air gratings 2)
Mounting wall cm 18 / 14 18 / 14
Floor cm 2 2
Ceiling cm 28 / 20 28 / 20
Brick lining for combustible wall cm 10 10
Weight
Meets requirement/limit values for:
Germany/ Austria / Suisse / Norway 1.BImSchV (Stufe 2) / 15a
BVG (2015) / LRV / NS 3059