Planning and installation - Panorama-Kamin 51/25/101/25 lifting door (easy-lift)
Tested according to EN 13229 W
Values measured at Rated capacity
Suitable for all construction types according to rules OK
EEI 105.7
Data for functional demonstration
Fire wood volume kg/h 4
Combustion performance kW 14.5
Flue gas mass flow g/s 12
Flue gas temperature after:
attached steel smoke hood °C 210
Necessary supply pressure Pa 12
Combustion air consumption m3
/h 35
Combustion air connection Ø mm 160
Heat distribution
Insert / heat accumulator % 50 / -
Glass pane (single / double) % 50 / -
Cross-section of gratings 1)
Supply air cm2 900 / - / -
Warm air cm2 900 / - / -
Minimal oven surface for closed construction type
Heat dissipating surface m2 5
Minimal distances of the fireplace
to insulation layer cm 6
to mounting floor cm 2
Thermal insulation without / with air gratings 2)
Mounting wall cm 10 / 6
Floor cm 0
Ceiling cm 19 / 14
Brick lining for combustible wall cm 10
Weight
Fireplace / combustion chamber kg 250 / 68
Meets requirement/limit values for:
Germany/ Austria / Suisse / Norway 1.BImSchV (Stufe 2) / 15a BVG (2015) / LRV / -