The Net Master Clock DTS 4806.masterclock is developed especially for a network environment. It is able to control conventional impulse clocks, self-setting MOBALine slave clocks, and is used as an accurate NTP time reference (time server) for computer systems.
Technical features
1 LAN ports (RJ45):
provides NTP (>250 requests/s)
Multi-purpose device due to the different time code and frequency outputs:
1x DCF/pulse/frequency current loop output
6x MOBALine / DCF active / Polarized Impulses
1x serial output
High precision time:
Time reception from GPS
The DTS 480x.masterclock can
be synchronized by a time signal
receiver (DCF 4500 or GPS
4500) and/or by NTP time servers (LAN / Internet).
The DCF current loop output can
be used to synchronize other
devices (e.g. master clocks).
The DTS 480x.masterclock is
equipped with 4 alarm control
inputs either to monitor other connected devices or to link external
signals (e.g. from sensors) to switching commands.
A serial RS 232 / RS 485 interface with configurable script file,
to output special synchronization
telegrams, completes the features
of this multipurpose master clock.
Alarms are signaled by a relay, with
SNMP traps or by e-mail.
By means of the management software MOBA-NMS, all DTS devices
can be fully operated and monitored.