for F30-F120 or EI30 - EI120 fire-protection walls
also for minimum remaining wall thickness ≤ 60 mm
also for directly opposing installation
with 4 screw domes and 2 expanding claw fields
Depth: 60 mm
Fixing screw spacing: 60 mm
Tube entries up to M25: 6
Cable entries of up to Ø 11.5 mm: 6
for sound insulation walls up to: 56 dB
DIBt approval: Z-19.21-2413
ETA approval: ETA-18/0091
Halogen-free: Yes
Packaging inner/dispatch: 10/100
Flush-mounting fire-protection box
In solid construction F30-F120 or EI30 - EI120 fire-protection walls, the fire-protection box receives the fire-protection period classification instead of fitted electrical installations. Even if the minimum wall thickness of 60 mm is not achieved in single-sided installation, or even in directly opposing installation, the fire-protection box ensures secure and smokeproof room separation. In the event of a fire, the integrated fire-retardant coating quickly and reliably seals the installation opening, so preventing smoke and flue gas from spreading. At the same time, the risk of the fire spreading because the remaining wall is not thick enough is prevented.
For F30-F120 or EI30-EI120 fire-protection walls
For minimum remaining wall thicknesses ≤ 60 mm
Also for directly opposing installation
Variable combination connection piece for conduits up to M25
With fire-protection cover, can be used as a junction box
Maintains the wall's sound insulation protection