Device emplacement
Indoor positioning
Heating capacity at 7/35 °C according to EN 14511
12kW
Heating capacity at -7/35 °C according to EN 14511
8.76kW
COP at 7/35 °C according to EN 14511
4.82
Suitable for additional heating central heating
No
Room temperature control
Yes
Type of regulation
Other
Kind of optimization
Other
External controller required
Yes
Suitable for hot tap water
No
Hot tap water control integrated
No
Suitable for active cooling
Yes
Cooling performance at 35/18 °C according to EN 14511
12kW - 12kW
Cooling performance at 35/7 °C according to EN 14511
8.66kW - 8.66kW
Suitable for swimming pool water heating
No
Swimming pool controls
No
Regulation for central heating boiler control
No
Regulation for buffer tank control
No
Modulating compressor
Yes
Modulation percentage
80% - 80%
Type of refrigerant
Other
Refrigerant pre-charge
0kg
Global warming potential (GWP)
0
Connection voltage
230V - 230V
Number of phases
1
Frequency
50 Hz
Fuse size of the device
2.3A
Width
795mm
Height
670mm
Depth
922mm
Weight
110kg
Sound level (in operation)
40dB(A) - 64dB(A)
Air temperature
5°C - 35°C
Air volume
3800m³/h - 3800m³/h
Max. heating water supply temperature
65°C
Nominal diameter central heating
1 inch external
Degree of protection (IP)
IP20
Cascadable
No
Remote operation
No
Data transfer via USB
No
Data transfer via internet
No
Data transfer via bus connection
Yes
Type voltage pump (system pump)
DC
Speed control pump (system pump)
Built-in (integrated)
Type of speed control (system pump)
Continuously variable
Connection and control multiple output systems possible
No
Sofstarter built-in
No