Tested according to EN 13229 W EN 13229 WA
Values measured at Rated capacity Accumulation
Suitable for all construction types according to rules OK OK
EEI 117.3 117.3
Data for functional demonstration
Fire wood volume kg/h 2.7 6
Combustion performance kW 12 20
Flue gas mass flow g/s 12 17
Outlet temperature (before heating surface) °C 470 580
Flue gas temperature after:
1 x adjoining cast iron radiator (GNF 8/10) °C 160 220
7 x accumulation rings (MAS) 1) °C 210 -
4,5 m ceramic accumulator 2) °C - 180
3,1 m accumulation stones (MSS) 2) °C - 215
Necessary supply pressure Pa 13 15
Combustion air consumption m3
/h 35 50
Combustion air connection Ø mm 125 125
Heat distribution
Insert / heat accumulator % 45 / 45 45 / 45
Glass pane (single / double) % - / 10 - / 10
Cross-section of gratings 3)
Convection air cm2 600 / 250 / 550 600 / 250 / 550
Supply air cm2 600 / 250 / 550 600 / 250 / 550
Minimal distances of the fireplace
to insulation layer cm 8 8
to mounting floor cm 15 15
Thermal insulation without / with air gratings 4)
Mounting wall cm 18 / 14 18 / 14
Floor cm 0 0
Ceiling cm 22 / 17 22 / 17
Isolation around the additional door 6 6
Brick lining for combustible wall cm 10 10
Weight
Fireplace / combustion chamber kg 80
Meets requirement/limit values for:
Germany/ Austria / Suisse / Norway 1.BImSchV (Stufe 2) / 15a BVG (2015) / LRV / -