LINIT fire protection panels withstand fires from the outside in accordance with fire resistance ratings F30 and W90. and a fire spread path of 1 meter. Consequently, they comply with DIN 4102, which applies mainly for high-rise and commercial buildings, public assembly places, hospitals, and schools. The system's main components consist of non-combustible materials of building material class A.
Facings and functional surfaces for every interior design and every requirement
Glass, aluminium or Glasal (fibre cement) are used for the outer facing. Behind the facing is a fire protection panel made of silicate (e.g. Promatect).
Insulation core
High-performance thermal insulation and protection (DIN 4108)
The insulation core consists of a mineral fibre panel with TCL 035. Of course, the requirements for thermal and soundproofing are also fulfilled apart from fire protection, so that all the structural-physical demands are met by one panel, without any additional measures.
Fire protection test - Officially tested & approved
LINIT fire protection panels F30/W90 were tested by the Construction Materials Testing Institute MPA (Materialprüfanstalt für das Bauwesen) in Braunschweig acc. to DIN 4102, Parts 2 and 3: F30 = P-3654/3420-MPA BS, W90 = P-3593/2810-MPA BS.