... CE marking-compliant in accordance with EN 15650. Fire test reports on main supports, assembly in all positions (blades horizontal and vertical), under 1500 Pa pressure and in both fire directions. Specially adapted ...
ALDES
... before you try to open the damper. Description Fire dampers represent passive fire protection, designed with the help of compartmentalization to prevent the spread of toxic gases, ...
... rectangular fire dampers work as separators between two fire sectors. They can be installed on both vertical and horizontal walls. They have a perimeter seal at both ends to ensure sealing between the ...
... Fire-fighting systems represent a specific range in accordance with the regulations. They are configured as elements of protection against fire and the passage of smoke, due to the smoke tightness required in the tests. The ...
... combustion and fire products from one segment to another by closing the air duct at the points of the fire separation constructions. Both in horizontal as well as vertical, depending on the model. Model CFDM. Fire ...
... The fire damper poppet valve SVA-FF is designed for installation in ventilation systems in accordance with DIN 18017-3. Besides, the fire damper poppet valve can also be mounted into ...
SCHAKO KG
... With its semi-rigid insulated core and .030 thick stucco, or optional smooth finish, this fire suppresion vent can fit the facade of any building. ...
... Circular fire dampers, KOOLAIR, model SCFC-PD, S/UNE-EN 1366-2:2000 EI-120 (ve i↔o) and (ho i↔o). Fire resistence 2 hours. Rectangular fire damper class EI-120. Dimensions ...
... switch for manual actuator Factory made pre fire break grouting The fire damper is CE marked according to the standard 15650:2010 and tested according to the test standard EN 1366-2. A fire ...
HALTON
... 0151.0320 Manufacturer: MAICO TS 18 DN 100 - short description Fire protection ceiling barrier for ER exhaust air systems, DN 100 TS 18 DN 100 - Product description Fire protection ceiling barrier for ER ...
... • The fire dampers FLX-EIS-120 work as a separator between two sectors of fire and ensure the same fire resistance that the structural elements of compartmentalisation, which limits ...
MADEL
... KTM Fire Dampers are used as fire barriers in general ventilation systems to separate two fire zone. Its main purpose is to prevent the spread of high temperature and smoke.They can be ...
VENCO A.S.
... CHARACTERISTICS: Fire dampers marked CE certified UNI EN 15650, UNI EN 13501-3 classified and tested according to UNI EN 1366/2. Installable on ventilation ducts ensure a rapid interruption of the air flow in case of ...
BROFER SRL
... Release temperature 72/95 °C Duct smoke detector RM-O-3-D Rectangular or square fire dampers for the isolation of duct penetrations between fire compartments.Tested for fire resistance ...
TROX
... Fire damper certified CE with termic cut and hot and cold smoke insulation according to EN1366-2. Technical specification: -Installed on low desity rigid wall EI180 (Ve i↔o) S(300Pa) -Installed on low desity flexible ...
... Fire dampers Mandik comply with EN 15650, EN 1366-2, EN 13501-3 + A1. Fire resistance EIS 120, 90 and 60 - depending on the needs of the customer can choose the damper meets the specified ...
FRANCE AIR
PANOL
... distance of 100mm between two fire dampers in the same wall or floor. Fire behaviour: automatic closure in less than 30 seconds when reaching 72 °C; insulation to heat and flame; indifferent to direction ...
MP3