Characteristics

Power source
PV
Connection
string
Phase
three-phase
Peak power

77 kW
(105 hp)

Description

Maximum profitability and versatility The M70A Flex Inverter has a peak efficiency of 98.8 % and has built-in and replaceable AC and DC-side Type 2 SPDs (surge protection devices). 6 MPP trackers are featured for optimum energy harvest on commercial rooftops with multiple angles as well as a wide input voltage range from 200 – 1100 V. Flexible system design For the system planner, maximum flexibility is ensured thanks to a wide input voltage range of 200 - 1000 V and 6 MPP trackers. The new unit is compatible with major types of PV modules and the robust IP65 rated enclosure allows outdoor installation. Simple Installation The lightweight and compact design of the M70A Flex greatly simplifies installation. The inverters include a unique wall mount bracket in the scope of delivery, allowing the units to be easily installed on a variety of wall surfaces. Max. input voltage - 1100 VDC Input voltage range - 200 to 1000 VDC MPP operating voltage range (full power) - 460 to 900 VDC Nominal voltage - 600 VDC Max. current - 156 A total, 26 A per MPP tracker Max. short-circuit current ISC - 50 A per MPP tracker Night time consumption - < 3.5 W 2) Max. number of MPP trackers - 6 DC Surge Protection Devices - Type 2 (EN 50539-11), replaceable, optional with combined Type 1+2 Max. apparent power - 77 kVA 3) Max. active power - 77 kW 3) 4) Nominal apparent power - 70 kVA 3) AC voltage range - 230/400V -20% / +30%; 5) 3 Phase + PE (Δ) or 3 Phase + N + PE (Y) Max. AC output current - 112 A Frequency range - 50 / 60 Hz ± 5 Hz 5) Adjustment range power factor - 0.8 cap to 0.8 ind Total harmonic distortion (THD) - < 3% at nominal apparent power

Catalogs

M70A Flex
M70A Flex
2 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.