Intro
Suitable for use in any type of 2 hour fire rated wall/ceiling system within a building that requires some form of containment, e.g. computer rooms, hospital wards, swimming pools etc.
Description
This panel is designed to fit into the structural membrane of jointless plasterboard wall/ceiling systems. It is supplied with a beaded frame to allow for tape and jointing on site and comes complete with a fully removable flush metal door. It is inserted directly into a pre-cut hole through the face of the wall/ceiling prior to wet finishes being applied. This is a 2 Hour Fire Rated Access Panel which has been tested to B.S.476: Part 22:1987.
Construction
Constructed from 1.2mm and 1mm thick Zintec Steel, with a polyester powder coating of matt white Ral 9010, 20% Gloss (other colours available upon request). The panels are also available in Stainless Steel for use in corrosive areas (quote using product code and ref SS). The removable flush metal door is filled with Rockwool insulation and sealed with a fire-resistant board and rear protection plate. The door is secured using a three point locking system and is fully sealed at the rear with an arrangement of silicone and intumescent seals.
Dimensions
Any panel sizes can be manufactured to order within maximum and minimum dimensional constraints. For further information please contact our Technical Sales Department.