Power supply (Vac) 230 (+6% -10%) – 50Hz
Absorbed power (W) 10
Max. motor load (W) 800
Accessories max. load (mA) 500
Electric lock max. load (VA) 15
Operating ambient temperature (°C) -20 +55
Protection fuses 2
Function logics Automatic/Semi-automatic/Safety/Semi-automatic B/ Dead Man C/Semiautomatic "Step by Step"
Opening / closing time Programmable (from 0 to 120 sec.)
Pause time 0, 10, 20, 30, 60, 120 sec.
Closing leaf delay 0, 5, 10, 20 sec.
Opening leaf delay 2 sec. (can be excluded per dip-switch)
Thrust force Adjustable per dip-switch on 8 levels for each motor
Terminal board inputs Open/Open free leaf/Stop/Limit Switch/Opening and Closing Safety
Devices/Power Supply + earth
Terminal board outputs Flashing lamp/Motors/Accessories power supply 24Vdc/Failsafe/Electric
lock 12Vac power supply
Quick-fit connector Genius 5PIN receivers
Selectable functions Logics and Pause times/ Thrust Force/ Opening and Closing Leaf Delay/
Reversing Thrust/ Failsafe/Closing Safety Device logic/ Pre-flashing
Programming key Simple or Complete work times learning with or without limit switches or
encoder, with or without slow-downs