Power supply (Vac) 230 (+6% -10%) – 50Hz
Absorbed power (W) 10
Max. motor load (W) 1000
Accessories max. load (mA) 500
Operating ambient temperature (°C) -20 +55
Protection fuses 2
Function logics Automatic/Automatic "Step by Step"/Semi-automatic/Safety/Semiautomatic B/Dead Man C/Semi-automatic "Step by Step"
Work time Programmable (from 0 to 4 minutes)
Pause time Programmable (from 0 to 4 minutes)
Thrust force Adjustable on 50 levels
Terminal board inputs Open/Partial open/Stop/Opening and Closing Safety Devices/Stop/Edge/
Power Supply + earth
Inputs in connector Limit switches in opening and closing/Encoder
Terminal board outputs Flashing lamp/Motor/24 Vdc Accessories Power Supply/Signalling lamp
24Vdc/Failsafe
Quick-fit connector Genius 5PIN receivers
Programming 3 keys (+, -, F) and display, simple or complete mode
Programmable functions Simple Mode Function logics/Pause time/Thrust force/Gate direction
Programmable functions Complete
Mode
Torque at start up/Braking/Failsafe/Pre-flashing/Indicator light/Safety device
logic/Encoder/Slow-downs/Partial opening time/Work time/Assistance
request/Cycles counter