SummaryDouble glazing with COOL-LITE® SKN 145 provides very high solar protection (solar factor g = 0.22) while maintaining moderate visible light transmission (TL = 41%). Solar-control glass with high selectivity and good thermal insulation. Typical composition used for calculations: 6-16-4 with coating on face 2.
Selection / environmental and performance arguments- Energy savings
- Reduced electricity for lighting and air conditioning: selectivity > 1.86
- Reduced heating losses (Ug = 1.1 W/m²·K)
- Thermal comfort: limits the risk of summer overheating and avoids the sensation of a cold surface in winter (suitable for conservatory roofs).
- Visual comfort: good natural light for the given level of solar protection and good access to outside views.
Applications- Rooflights or glazed roofs
- Large glazed façades oriented south or west in hot sunny climates, or façades without additional exterior solar protection (e.g. high-rise building façades)
Advantages- Slightly shimmering bluish appearance, color stable and homogeneous at different viewing angles
- Very high solar protection (g = 0.22), reducing cooling needs
- High thermal insulation (Ug = 1.1 W/m²·K) to limit heat loss
- Enables large glazed spaces while preserving visual and thermal comfort
Performance (excerpts)Product | TL (%) | RL ext (%) | RL int (%) | Solar factor (g) | Selectivity | U (W/m²·K)
SKN 145 | 41 | 19 | 15 | 0.22 | 1.86 | 1.1
Range and availability- Available as monolithic glass in thicknesses 6 or 8 mm (other thicknesses on request)
- Standard dimensions 6000 x 3210 mm (other lengths available on request)
- Also available as laminated safety glass (from 44.2 to 88.2) and in STADIP® PROTECT or STADIP® SILENCE versions for enhanced acoustic insulation
Usage instructions- Must always be assembled in an insulating glazing unit with the coating placed on face 2
- Edge deletion of the coating is mandatory
Characteristics / technical specifications- Visible light transmission (TL): 41 %
- External light reflection (RL ext): 19 %
- Internal light reflection (RL int): 15 %
- Solar factor (g): 0.22
- Selectivity: 1.86
- Thermal transmittance Ug (double glazing, argon 90 %): 1.1 W/m²·K
- Typical composition indicated: 6-16-4 with coating on face 2 (values given according to EN 673 and EN 410)
- Product from the 'les engagés' range (enhanced environmental and health performance)
- Appearance: slightly shimmering bluish, color stable at different angles
- Typical applications: façades, roofs, rooflights, high-rise buildings