Panel cladding JI 25-267-1070
steelribbedfor harsh environments

Panel cladding - JI 25-267-1070 - Joris Ide - steel / ribbed / for harsh environments
Panel cladding - JI 25-267-1070 - Joris Ide - steel / ribbed / for harsh environments
Panel cladding - JI 25-267-1070 - Joris Ide - steel / ribbed / for harsh environments - image - 2
Panel cladding - JI 25-267-1070 - Joris Ide - steel / ribbed / for harsh environments - image - 3
Add to favorites
Compare this product

Characteristics

Configuration
panel
Material
steel
Finish
ribbed
Technical characteristics
for harsh environments

Description

Summary
Ventilated cladding profiles are suitable for livestock, storage and other buildings requiring continuous ventilation. Built-in profile openings ensure optimized air circulation while limiting water ingress. The number and arrangement of openings can be adapted to project requirements. This profile is available with several coatings and finishes.

Main use
  • Ventilated cladding for livestock buildings, storage and other structures requiring continuous ventilation.
  • Reduces water ingress while allowing airflow.
  • Number and arrangement of openings adjustable per project.

Dimensions
Length: Min. 1500.0 mm / Max. 4000.0 mm
Width: Max. 1070.0 mm

Thickness and weight
0.63 mm: 5.64 kg/m²
0.75 mm: 6.71 kg/m²

Material
Steel S320 GD

Available coatings
The product is available with several coil coating systems. Main coatings shown on the product sheet:
  • Essential (25 µ) — Base coating for exterior use (cladding, roofing and accessories, HVAC units).
  • Ultra — For severe exterior environments: profiles, sandwich panels for roofs and cladding, building materials (tiles, gutters, etc.).

Shades / colours (extracts from available coatings)
Essential (25 µ) — colours listed
  • 01002 — RAL 1002
  • 01013 — RAL 1013
  • 01015 — RAL 1015
  • 01019 — RAL 1019
  • 01021 — RAL 1021
  • 02001 — RAL 2001
  • 03000 — RAL 3000
  • 03009 — RAL 3009
  • 05002 — RAL 5002
  • 05008 — RAL 5008
  • 05010 — RAL 5010
  • 05011 — RAL 5011
  • 05014 — RAL 5014
  • 05015 — RAL 5015
  • 05017 — RAL 5017
  • 06003 — RAL 6003
  • 06005 — RAL 6005
  • 06009 — RAL 6009
  • 06011 — RAL 6011
  • 06020 — RAL 6020
  • 06021 — RAL 6021
  • 07006 — RAL 7006
  • 07012 — RAL 7012
  • 07015 — RAL 7015
  • 07016 — RAL 7016
  • 07021 — RAL 7021
  • 07022 — RAL 7022
  • 07032 — RAL 7032
  • 07035 — RAL 7035
  • 07037 — RAL 7037
  • 07042 — RAL 7042
  • 08004 — RAL 8004
  • 08011 — RAL 8011
  • 08012 — RAL 8012
  • 08014 — RAL 8014
  • 08019 — RAL 8019
  • 08024 — RAL 8024
  • 08025 — RAL 8025
  • 09001 — RAL 9001
  • 09002 — RAL 9002
  • 09005 — RAL 9005
  • 09006 — RAL 9006
  • 09007 — RAL 9007
  • 09010 — RAL 9010
  • 09016 — RAL 9016
  • 50004 — Woodstructure
  • 70003 — 1102 Rouge Tuile
  • 90007 — 4750 Gris Nuage

Ultra — colours listed
  • 01015 — RAL 1015
  • 05008 — RAL 5008
  • 07015 — RAL 7015
  • 07016 — RAL 7016
  • 07021 — RAL 7021
  • 07022 — RAL 7022
  • 07035 — RAL 7035
  • 08012 — RAL 8012
  • 09002 — RAL 9002
  • 09005 — RAL 9005
  • 09006 — RAL 9006
  • 09007 — RAL 9007
  • 09010 — RAL 9010

Reference standards
Galvanized steel: NF EN 10346:2015 - tolerances according to NF EN 10143:2006 - NF P34-310:2017
Coil coating: NF EN 10169:2022 - NF P34-301:2017
Tolerance: Professional recommendations RAGE cladding July 2014
Calculations and tests: Tests according to NF P 34-503-1:2024 interpreted per Recom. Prof. RAGE 2014 (annexes D, E and N for wind Eurocode NF EN 1991-1-4+NA:2012 and annexes K, E and N for wind Rules NV65 modified 2009).

Remarks
Profile designed for ribbed cladding with integrated ventilation options. Available in multiple widths/lengths and in different thicknesses according to project needs. Finishes (Essential, Ultra, etc.) imply different performances and recommended uses (standard use vs severe environments).